Note:
|
An approximate 3-meter cable
is Factory-Supplied, and comes out of the
base of the searchlight, with bare wires
on the end. All other cables shown (1, 2,
3, 4, 5 and 6) must be supplied by the customer.
The customer must supply a junction box,
as seen in the picture. DC current flows
through Cable 1. One Master Control Station
is required for each light, and any number
of slaves can be added. The Electronic Power
Supply must be mounted indoors, out of the
weather, and placed within 25 meters from
the searchlight. Ampere values are approximate...select
wire-sizes with respect to amp-load, distance,
temperature and all applicable electrical
codes. Consult AutoCad wiring diagram, included
inside installation manual, prior to connecting
wires to Searchlight, Power Supply and Control
Stations. For optional "weatherproof"
electronic supply, and optional anti-icing heater circuitry, please
consult factory
CAUTION: Above information subject
to change without notice |
200
Watt Dimensions in inches (mm)

Power Supply:
Compact
Electronic Current-Regulated Supply. Regulated
Current increases lamp-life and keeps searchlight
intensity constant despite voltage input
changes. Solid
State Electronics includes Universal Power
Input Feature, providing 115 Volts AC and
230 Volts AC inputs on the same printed
circuit board. |

Joystick Control Stations:
Remote
control functions include Lamp ON/OFF, Electric
Beam-size Focus, and Advanced Joystick which
controls Speed and Direction simultaneously
with one hand¡¦ ¡°move the joystick to the
first position and it will move slowly,
move it further and it will go faster¡±.
One Master Station (C4-2-1) is required
with each system, and any number of Slave
Stations can be added: Indoor Console Flush-Mount
(C4-2M-1), Outdoor Console Flush-Mount (C4E2M-1-1)
or Outdoor Station Mounted in Weatherproof
Box (C4E2M). |


Weight
in Pounds (Kilograms)
Searchlight Model XY2EDE-24ARF |
Power Supply 2PS115/230 |
Master Station C4-2-1 |
Indoor Slave Station C4-2M-1 |
Outdoor Slave Station C4E2M
and C4E2M-1-1 |
45lb(20.5kg) |
7.5lb(3.4kg) |
4lb(1.8kg) |
2lb(.9kg) |
2lb(.9kg) |
How to Specify a System¡¦
Start
at the left and read across table. Select Standard or
Upside Down-Mounted Searchlight, 115 Volt or 220 Volt
Power Supply, and one C4-2-1 Master Station. Any combination
and any quantity of Slave Stations can be added. Select
C4-2M-1 for a Console Flush-Mount, Indoors. Select C4E2M-1-1
for a Weatherproof Console Flush-Mount, Outdoors. Select
C4E2M for a Slave Station mounted in a Weatherproof
Box.
Searchligh
Standard or Upside Down |
Power Supply
115VAC or 220VAC |
Master Station
(Indoors) |
Slave Station
Console Flush-Mount
(Indoors) |
Slave Station
Console Flush-Mount
(Outdoors) |
Slave Station
Weatherproof Box
(Outdoors) |
XY2EDE-RF
or XY2EDE-BURF |
2PS115
or
2PS230 |
C4-2-1 |
C4-2M-1 |
C4-2M-1-1 |
C4E2M |
Sample Specification:
A
200 Watt Xenon Searchlight mounted Upside Down, 220
Volts, with Qty (2) Indoor Console Flush-Mount Stations,
and Qty (1) Outdoor Console Flush-Mount Station. Select
Searchlight XY2EDE-BURF, Power Supply 2PS230, Qty (1)
Master Station C4-2-1, Qty (1) Slave Station C4-2M-1
and Qty (1) Slave Station C4E2M-1-1.
Specifications
not guaranteed and subject to change without notice.
Select Searchlight XY2EDE-BURF, Power
Supply 2PS230, Qty (1) Master Station C4-2-1, Qty (1)
Slave Station C4-2M-1 and Qty (1) Slave Station C4E2M-1-1.
Specifications
not guaranteed and subject to change without notice.
¢º
GO TO THE BACK |